Surgical
Options

Collagen
Bandage
Visco-
Elastics
Iris
Expansion
OASIS®
Instruments
FEATHER®
Instruments
Preference
Cards

All options available for US partners. Order now using MYOASIS360.com

Explore Surgical
Resource Pages

All options available for US partners.
Tap here to see how to order.

Step By Step Guide

Transferring The Iris Expander

IMPORTANT: During this process, be careful not to induce rigorous motion or drop the Iris Expander onto the sterile field.

1

Expose the OASIS Iris Expander by holding the packaging in the dominant hand. Peel back the Tyvek cover with the other hand to transfer to the sterile scrubbed assistant.

2

The scrubbed assistance can remove the Iris Expander from the packaging by grasping the Iris Expander with their dominant hand index finger and thumb at the neck of the inserter handle. Then, gently pull product out of the carton.

Loading the Iris Expander

IMPORTANT: Do not retract the slide button until after pre-folding the Iris Expander in Step 4.

3

Position the holder and inserter so that the word OASIS is facing up in dominant hand.

4

Prefold the Iris Expander within the holder by pulling the inserter down by its handle until its tip is between the two translucent dots on the holder. Once folded into position, then slide back the button until the Iris Expander is completely retracted into the inserter.

Placing the Iris Expander

5

After viscoelastic has filled the anterior chamber, advance the tip of the inserter tube into the anterior chamber. Move the slide button forward to push out and release the Iris Expander from the inserter onto the anterior surface of the iris.

6

Use a Sinskey II or similar instrument to push the pocket into the pupillary space. Engage the iris margin in the pocket at each corner by placing one proximal pocket first using the positioning holes, then place the opposing distal pocket. Repeat with other proximal pocket and final distal pocket.

Removing the Iris Expander

5

Usea collar button, Kuglen or similar instrument to engage the middle of the proximal crossbar and push toward the center of the pupil to disengage both proximal corner pockets.

6

Place the same instrument underneath the proximal crossbar and pull the Iris Expander through the wound to remove and discard the Iris Expander.

All Resources.

Instructions For Use (IFUs)

OASIS Iris Expander Instructions For Use

Reimbursement Information

Medicare Reimbursement For Mechanical Pupil Dilation with Oasis Iris Expander

Product Information

OASIS Iris Expander Product Sheet

OASIS Iris Expander® Instructional Wall Chart